Fiber Cables
Outdoor, underground, aerial self-supporting, utility, air-blowing, and FTTH drop cables. Click any row to expand full technical parameters.
11 CABLE TYPES
DA-GYTA
GYTA — Stranded Loose Tube, APL Armored
Standard outdoor duct & aerial cable. Steel wire CSM, laminated aluminum tape armor.
DuctAerialAPL ArmorOutdoor
Technical Parameters
Fiber TypeSM / MM
Attenuation @1310nm≤ 0.36 dB/km
Attenuation @1550nm≤ 0.22 dB/km
Central Strength MemberSteel wire
ArmorLaminated aluminum tape (APL)
Outer JacketBlack PE
Bending Radius10D static / 20D dynamic
Operating Temperature−40°C to +70°C
Water BlockingLongitudinal gel filling
Installation & Key Features
  • Duct installation (conduit or HDPE pipe)
  • Aerial deployment with messenger wire
  • APL armor provides moderate crush & rodent resistance
  • Steel wire CSM ensures high tensile performance
  • Black PE jacket — UV and weathering resistant
  • Gel-filled tubes prevent water migration
DA-GYTS
GYTS — Stranded Loose Tube, PSP Armored
Enhanced crush resistance via corrugated steel tape. Duct and aerial installation.
DuctAerialPSP ArmorCrush Resistant
Technical Parameters
Fiber TypeSM / MM
Attenuation @1310nm≤ 0.36 dB/km
Attenuation @1550nm≤ 0.22 dB/km
Central Strength MemberSteel wire
ArmorCorrugated steel tape (PSP)
Outer JacketBlack PE or LSZH
Bending Radius10D static / 20D dynamic
Operating Temperature−40°C to +70°C
Installation & Key Features
  • Duct installation in conduit or HDPE pipe
  • Aerial with messenger wire
  • PSP armor offers superior crush resistance vs APL
  • Recommended for higher mechanical load environments
  • Compatible with standard optical splicing equipment
DA-GYFTY
GYFTY — All-Dielectric, Metal-Free Outdoor
Fully metal-free FRP construction. Safe for HV corridors and strong EM environments.
Metal-FreeFRPHigh-EM ZoneNo Grounding
Technical Parameters
Fiber TypeSM / MM
Attenuation @1310nm≤ 0.36 dB/km
Attenuation @1550nm≤ 0.22 dB/km
Central Strength MemberFRP (non-metallic)
ArmorNone — all-dielectric
Metal ContentZero
Outer JacketBlack PE
Operating Temperature−40°C to +70°C
Installation & Key Features
  • Duct or aerial (non-self-supporting)
  • High-voltage power line corridors
  • Strong electromagnetic environments
  • No grounding hardware required at any termination
  • FRP CSM — high tensile, lightweight
DA-GYTY53 / DA-GYTA53
GYTY53 & GYTA53 — Direct Buried
PSP-armored double-jacket cables for direct buried underground installation without conduit.
Direct BuriedPSPDouble JacketGYTA53: APL+PSP
Technical Parameters
Fiber TypeSM / MM
Attenuation @1310nm≤ 0.36 dB/km
Attenuation @1550nm≤ 0.22 dB/km
GYTY53 ArmorCorrugated steel tape (PSP)
GYTA53 ArmorAPL + PSP (double armor)
JacketDouble black PE
Max Fiber Count144 fibers (GYTY53)
Operating Temperature−40°C to +70°C
Installation & Key Features
  • GYTY53: Direct buried in soft to moderate soil
  • GYTA53: Aggressive/rocky soil; maximum mechanical protection
  • Water-blocking compound between double jackets
  • Steel wire CSM for high tensile during pulling
  • GYTA53 preferred for railway and highway crossings
DA-ADSS
ADSS — All-Dielectric Self-Supporting Aerial
Fully metal-free self-supporting aerial. Safe for HV power line corridors. No grounding required.
Self-SupportingMetal-FreeHigh-VoltageAnti-Track PE≤144f
Technical Parameters
Fiber TypeSM G.652D / G.657A2
Attenuation @1310nm≤ 0.36 dB/km
Attenuation @1550nm≤ 0.22 dB/km
Central Strength MemberFRP (non-metallic)
JacketAT (anti-tracking) PE or standard PE
Jacket OptionsSingle or double jacket
Metal ContentZero — fully dielectric
Max Fiber Count144 fibers
Operating Temperature−40°C to +70°C
Installation & Key Features
  • Aerial self-supporting on utility poles and towers
  • High-voltage power line corridors (no grounding required)
  • Anti-rodent variant available (flat FRP armor layer)
  • AT jacket prevents electrical tracking in HV corridors
  • Aramid yarn water blocking for outdoor sealing
DA-GYXTW
GYXTW — Compact Central Tube, PSP Armored
Uni-tube design with parallel steel wire strength members. Compact, cost-effective for ≤24 fiber runs.
Central Tube≤24 FibersCompactPSP
Technical Parameters
Fiber TypeSM / MM
Attenuation @1310nm≤ 0.36 dB/km
Attenuation @1550nm≤ 0.22 dB/km
Tube ConstructionUni-tube (central tube)
Strength MemberTwo steel wires (parallel)
ArmorCorrugated steel tape (PSP)
Outer JacketBlack PE
Max Fiber Count24 fibers
Operating Temperature−40°C to +70°C
Installation & Key Features
  • Duct installation (conduit or HDPE pipe)
  • Aerial with messenger wire (non-self-supporting)
  • Compact uni-tube — smaller OD vs stranded tube
  • Recommended for runs requiring ≤24 fibers
  • High cost-performance ratio for low-count applications
DA-EPFU / DA-GCYFY
Air Blowing Micro Cables — EPFU & GCYFY
Lightweight blown-fiber micro cables for FTTH and metro access. Optimized aerodynamic profile for pneumatic installation.
Air BlowingFTTHMicro Duct2–288f
EPFU — Indoor Micro Cable
ConstructionUni-tube; UV cured resin
Outer SheathPolymer outer sheath
Min. Micro Duct5/3.5mm OD/ID
ApplicationFTTH indoor air blowing
GCYFY — High-Density Blown
ConstructionStranded loose tube
Fiber Count2 ~ 288 fibers
ApplicationMetro access + FTTH
Key PropertyBest blowing; high duct utilization
Installation & Key Features
  • Pneumatic (air blowing) into HDPE micro ducts
  • EPFU: FTTH indoor runs in 5/3.5mm+ micro ducts
  • GCYFY: 2–288 fibers in a single compact cable
  • Aerodynamically optimized for long blowing distances
  • Lightweight and flexible — easy to re-blow or replace
DA-OPGW / DA-OPPC
OPGW & OPPC — Power Line Utility Cables
Dual-function utility cables combining optical fiber with HV power line ground wire or phase conductor.
OPGWOPPCHV Power LineLightning Protection
OPGW Variants
Central TubeSteel optical fiber unit in center
Stranded TubeAS wires + OP unit (stranded)
Al-clad SSTAS wires + AL(SUS) tube + fiber
Al-clad PBTPBT loose tube + FRP + Al-clad wire
FunctionGround wire + optical fiber comms
Installation & Key Features
  • OPGW: Strung on HV towers as the overhead ground wire
  • OPPC: Replaces one phase conductor on HV lines
  • Used on 66kV, 110kV, 220kV, 500kV systems
  • Simultaneous lightning protection + fiber backbone
  • Eliminates separate fiber cable on power corridors
DA-GJX / DA-GJYX / DA-GJYXHA
FTTH Drop Cables — Indoor, Aerial & Armored
Flat and round FTTH drop cables for indoor horizontal, aerial self-supporting, and armored duct deployment.
FTTHIndoorAerial DropLSZH≤4 Fibers
GJX — Indoor Flat Drop
Fiber Count1 ~ 4 fibers
Strength MembersSteel wire or FRP/KFRP
JacketBlack LSZH
Attenuation @1310nm≤ 0.4 dB/km
Attenuation @1550nm≤ 0.3 dB/km
GJYX — Outdoor Aerial Drop
Messenger WireSteel wire (self-supporting)
JacketBlack LSZH
GJYXHA ArmorAPL + water blocking tape
Installation & Key Features
  • GJX: Indoor horizontal runs to subscriber outlet
  • GJYX: Aerial last-mile connection, pole to premises
  • GJYXHA: Armored variant for protected duct runs
  • LSZH jacket — low smoke & zero halogens for fire safety
  • G657A2 bend-insensitive fiber option available
DA-IC-SM-D / DA-IC-SM-B / DA-GJPFWQH
Indoor Cables — Distribution, Breakout & Mini Distribution
Tight-buffer indoor cables for horizontal & vertical in-building cabling. Includes 144f mini distribution (13mm OD).
IndoorPVC/LSZHUp to 144fG657A2
Shared Parameters
Fiber TypeSM / MM
Attenuation @1310nm≤ 0.4 dB/km
Attenuation @1550nm≤ 0.3 dB/km
JacketPVC or LSZH
Bending Radius10D static / 20D dynamic
Operating Temperature−20°C to +60°C
Distribution (D-type)2~48f; 0.9mm tight buffer
Breakout (B-type)2~24f; sub-cable unit
Mini Distribution24~144f in 13mm OD; G657A2
Installation & Key Features
  • D-type: Horizontal in-building cabling rack to rack
  • B-type: Vertical riser and horizontal applications
  • Mini: High-density data centers and IDF/MDF rooms
  • Mini: 144 cores in only 13mm OD — industry-leading density
  • G657A2 bend-insensitive for tight-radius indoor routing
// Category 02
Active Equipment
EPON/GPON OLTs, dual-mode ONUs, CATV optical transmitters and receivers, EDFA/EYDFA amplifiers, media converters, and optical transceivers.
7 PRODUCTS
EPON OLT
DA-GE9102
EPON OLT
Carrier-grade EPON Optical Line Terminal for broadband FTTH networks. Up to 16 PON ports with 1:64 splitting ratio.
  • Max transmission: 20 km
  • Splitting ratio: 1:64 max
  • Downlink speed: 1.25 Gbps
  • PON ports: 2 / 4 / 8 / 16; SFP slot interface
  • Install: 1U rack mount
  • Power: Single AC / Dual AC / Dual DC
EPON1U Rack1.25G
GPON OLT
DA-GP1108
GPON OLT
High-capacity GPON OLT with 1:128 splitting ratio and 2.5 Gbps downlink for next-generation broadband deployments.
  • Max transmission: 20 km
  • Splitting ratio: 1:128 max
  • Downlink speed: 2.5 Gbps
  • PON ports: 8 / 16; SFP slot interface
  • Dimensions: 442×320×44mm (1U)
  • Power: Dual AC / Dual DC
GPON1U Rack2.5G
Dual Mode ONU
DA-GPE12
Dual Mode ONU — GPON/EPON
Desktop subscriber ONUs compatible with both GPON and EPON networks. Multiple port configurations for voice, data, and CATV.
  • Downlink: 2.5 Gbps; 1× SC optical port
  • Data: 1 / 2 / 4× RJ-45
  • POTS optional: 1 / 2× VoIP port
  • CATV optional: 1× RF port
  • Power: 12V/1A; temp: 0~+50°C
ONUGPON/EPONTriple-Play
CATV Optical Transmitter
DA-CATV-T
CATV Optical Transmitter
1U rack-mounted CATV transmitter for analog RF signal distribution over fiber. 1310nm and 1550nm laser options.
  • Bandwidth: 45 ~ 1000 MHz
  • Optical interface: SC/APC or FC/APC
  • Wavelength: 1310nm or 1550nm
  • Output: 2~16 mW (1550nm); 2~36 mW (1310nm)
  • Transmission distance: 20 km
  • Dimensions: 483×380×44.5mm (1U)
CATV1310/1550nm1U
CATV Optical Receiver
DA-CATV-R
CATV Optical Receiver
Indoor and outdoor CATV optical receiver for RF signal recovery at subscriber distribution points. SC/APC and SC/UPC optical inputs.
  • Bandwidth: 45 ~ 1000 MHz
  • Optical interface: SC/APC or FC/APC
  • Reception wavelength: 1100 ~ 1600 nm
  • RF output ports: 1 / 2 / 4
  • Input power range: −7 ~ +2 dBm
  • Application: Indoor or outdoor
CATVRF OutputIndoor/Outdoor
EDFA EYDFA Amplifiers
DA-EDFA / DA-EYDFA
EDFA & EYDFA Fiber Amplifiers
Erbium-doped fiber amplifiers for 1550nm signal amplification. Single-port EDFA and high-power multi-port EYDFA configurations.
  • Wavelength: 1550 ± 20 nm
  • EDFA output: 13~28 dBm; ports: 1/2/4
  • EYDFA output: 29~44 dBm; ports: 8/16/32/64
  • Interface: SC/APC or FC/APC
  • Power: AC 90~265V or DC 48V
EDFAEYDFA1550nm
Optical Transceivers SFP to 100G
DA-SFP / DA-SFP+ / DA-XFP / DA-QSFP / DA-AOC
Optical Transceivers — SFP to 100G
Full range of optical transceivers and active optical cables from 1.25G to 100G for all switch and router platforms.
  • Data rates: 1.25 / 2.5 / 10 / 40 / 100 Gbps
  • Transmission distance: 0.55 ~ 100 km
  • Types: SFP, XFP, SFP+, QSFP, AOC
  • Optical interfaces: LC, SC, MPO
  • Industrial temp: −40~+85°C
SFP+QSFP100G
// Category 03
Test Equipment
OTDR field units, optical power meters, light sources, visual fault locators, and cable blowing machines.
5 PRODUCTS
OTDR Field Unit
DA-OT5000
OTDR — Field Unit
Portable OTDR for outdoor cable loss testing and breakpoint location up to 240km. Multi-wavelength with optional PON module.
  • Wavelengths: 850/1300/1310/1490/1550/1625nm
  • Dynamic range: 45/43 dB (max. 240km)
  • Optional: PON power meter module
  • Built-in OPM + VFL + MCI (high-config)
OTDR45dB240km
OTDR Platform
DA-OT5200
OTDR Platform — SM/MM Combined
High-precision OTDR platform combining SM and MM wavelength testing in one modular unit with 8" TFT touch screen.
  • Display: 8" TFT touch screen
  • SM + MM wavelength in one unit; 50 dB dynamic range
  • Modular: optional OPM / light source / connector inspector
OTDRSM+MM50dB
Power Meter Light Source
DA-OPM / DA-LS / DA-MPM
Optical Power Meter & Light Source
Auto-wavelength identification power meter with 1000-record storage, USB transfer, and matching multi-wavelength light source.
  • Light source wavelengths: 850~1625nm (1–4 selectable)
  • Power meter range: −70 ~ +6 dBm; auto-wavelength ID
  • Storage: 1000 records; USB data transfer
  • Connector: SC/FC/ST interchangeable
Power MeterLight SourceAuto-λ
VFL
DA-VFL
Visual Fault Locator (VFL)
Pocket-sized 650nm visible red laser for identifying fiber continuity, breakpoints, bends, and connector end-face defects.
  • Laser wavelength: 650nm (visible red)
  • Detection distance: 5km or 12km variants
  • Compact pen-style form factor
  • Suitable for SM and MM fiber types
VFL650nm12km
Cable Blowing Machine DA-ABM
DA-ABM-M28-P / DA-ABM-L825-PH
Cable Blowing Machines — Mini & Hydraulic
Pneumatic and hydraulic cable blowing machines for installing blown-fiber micro cables into HDPE micro duct networks.
  • DA-ABM-M28-P: Mini; pneumatic; cable 3~10mm; duct 8~20mm
  • DA-ABM-L825-PH: Hydraulic; cable 8~25mm; duct 32~50mm; pump included
  • Air compressor not included with either unit
Air BlowingPneumaticHydraulic
// Category 04
Cable Management
Optical distribution frames, network cabinets, patch panels, dome and inline splice closures, outdoor cross-connect cabinets, and FAT boxes.
7 PRODUCTS
ODF
DA-ODF-HA / DA-ODF-HD
ODF — Optical Distribution Frame
Floor-standing ODFs for central offices and headends. Up to 720 fibers with integrated 12-core splice trays.
  • Capacity: 504f / 576f / 720f
  • 12-core integrated splice trays per unit
  • Module options: 24 / 48 / 72 / 144 cores per unit
  • Heights: 2.0m / 2.2m / 2.6m
  • Cold-rolled steel; electrostatic spraying finish
Indoor720fFloor Stand
Network_Cabinet
DA-NC Series
Network Cabinets — Wall & Floor Type
Full range from 6U wall-mount to 47U floor-standing with 800kg load rating and adjustable depth pillars.
  • Wall-mount: 6~18U; max 60 KG static load
  • Floor type: 22~47U; max 800 KG static load
  • Open frame rack: 42/47U; 4-post; 400 KG
  • Adjustable depth equipment mounting pillars
6U–47U800 KGWall/Floor
Patch_Panel
DA-ODB-RM2 / DA-ODB-RM7C
Rack-Mounted Fiber Patch Panels
Fixed, sliding, and rotating rack-mounted patch panels from 1U to 4U for all standard adapter interfaces.
  • Types: Fixed / Sliding / Rotating
  • Capacities: 1U 12/24SC → 4U 96/144SC
  • Adapters: SC / DSC / DLC / ST / FC / E2000
  • Indoor central office and data center use
1U–4URack MountSC/LC/FC
Dome_Closure
DA-FOSC-C568 / DA-FOSC-DH Series
Dome Type Splice Closures — IP68
Weatherproof dome splice closures in mechanical and heat shrink seal variants. Up to 672 cores, IP68 rated.
  • Mechanical seal: 72 / 144 / 288 cores; 4~6 branch ports
  • Heat shrink seal: 96 ~ 672 cores; up to 16 branch ports
  • Protection: IP68
  • Install: Wall / Pole / Aerial / Direct buried
DomeIP68672f
Inline_Closure
DA-FOSC-C636 / DA-FOSC-C688B / DA-FOSC-C661
Inline Splice Closures — IP68
Low-profile rectangular inline closures for through-cable joints. Screw or buckle fastening, up to 288 cores.
  • Capacities: 96 / 144 / 288 cores
  • Cable ports: 2-in/2-out or 3-in/3-out
  • Protection: IP68
  • Install: Wall / Aerial / Direct buried
InlineIP68288f
FAT_Box
DA-ODN-OP-IS-16W / DA-ODN-GFS10
FAT Box & Fiber Distribution Boxes
Pre-connectorized fiber access terminal boxes and distribution boxes for FTTH last-mile deployment.
  • FAT DA-ODN-OP-IS-16W: 16 pre-connected adapters; IP65
  • DA-ODN-GFS10: IP68; integrated PLC splitter; wall/pole mount
  • Compact and lightweight; fast connector compatible
IP65/68Pre-ConnectFTTH
OCC
DA-OCC / DA-ONC Series
Outdoor Cross-Connect Cabinet (OCC)
IP65/IP55 rated outdoor cabinets for street-level fiber distribution and cross-connection.
  • DA-OCC: SMC; 96/144/288/576/1152f; IP65
  • DA-ONC-576SMC: Passive; SMC; 22U; IP65
  • Install: Wall / Pole / Ground mounted
IP651152fSMC
// Category 05
Passive Components
PLC splitters, fiber optic adapters, patchcords, and pigtails.
3 PRODUCTS
PLC_Splitter
DA-PLC
PLC Splitter — 1×2 to 1×128
Planar lightwave circuit splitters with excellent channel uniformity in six packaging configurations for every deployment scenario.
  • Splitting ratio: 1×2 to 1×128
  • Return loss: ≥55 dB; Low PDL; Low excess loss
  • Types: Blockless / Box / Insert / LGX / Rack-mount / Bare fiber
  • Fiber: SM only
PLC1×128FTTH/PON
Fiber Optic Adapters
DA-AD
Fiber Optic Adapters / Couplers
SM and MM fiber adapters in all standard interfaces. Insertion loss ≤0.2 dB, return loss ≥55 dB.
  • Types: SC / LC / FC / ST / E2000
  • UPC and APC versions
  • Insertion loss: ≤0.2 dB; Return loss: ≥55 dB
  • Housing: Plastic or metal
AdapterSC/LC/FCUPC/APC
Patchcords
DA-SC / DA-FC / DA-LC / DA-PC
Patchcords & Pigtails
Full range of SM and MM patchcords and pigtails across all standard connector types, polish grades, and jacket materials.
  • Connectors: SC / FC / ST / LC / E2000
  • Polish: UPC & APC; Fiber: SM & MM
  • Jacket: PVC or LSZH
  • IL: ≤0.3 dB; RL: MM ≥35 / SM UPC ≥50 / SM APC ≥60 dB
PatchcordPigtailUPC/APC
// Category 06
Tools & Ducts
Fusion splicers, SMC manholes, and FTTH field termination toolkit.
3 PRODUCTS
Fusion Splicer
DA-FS1230-I / DA-FS1290-I
Fusion Splicer — 4 & 6 Motor
Feeder-type fusion splicers with precision core-to-core alignment. 4-motor and 6-motor variants for distribution and backbone cable.
  • Types: Backbone / Feeder / FTTH compact
  • Fiber: SM and MM; single fiber fusion
  • Splice loss: SM 0.02 dB typical; MM 0.01 dB typical
  • Splicing time: 6 seconds
  • Display: 5" high-resolution LCD touch screen
Core Alignment6-MotorSM/MM
DA-MH
SMC Manholes
Non-metallic SMC manholes for underground fiber duct access points. EN1240 rated across four traffic load classes.
  • Material: SMC non-metal
  • Load classes: EN1240 A50 / B125 / C250 / D400
  • Direct bury — no concrete pad required
  • Lockable covers on all variants
ManholeSMCEN1240
FTTH Termination Toolkit
DA-TK300S(P)
Tool Kit — FTTH Termination (TK300)
Compact toolkit for FTTH subscriber-end termination including drop cable preparation and fast connector installation.
  • Optimized for flat LSZH drop cable preparation
  • Compatible with all standard fast connectors (SC/LC/FC)
  • Lightweight portable carry bag format
  • Suitable for daily FTTH deployment technician work
FTTHTerminationFast Connector
Technical Reference

Cable Specification Summary

ProductFiber CountArmorJacket@1310nm@1550nmTemp (°C)InstallationMetal-Free
GYTACustomAPLBlack PE≤0.36 dB/km≤0.22 dB/km−40~+70Duct / AerialNo
GYTSCustomPSPBlack PE/LSZH≤0.36 dB/km≤0.22 dB/km−40~+70Duct / AerialNo
GYFTYCustomNoneBlack PE≤0.36 dB/km≤0.22 dB/km−40~+70Duct / Aerial / EMYes
GYTY53144f maxPSPDouble PE≤0.36 dB/km≤0.22 dB/km−40~+70Direct buriedNo
GYTA53CustomAPL + PSPDouble PE≤0.36 dB/km≤0.22 dB/km−40~+70Direct buried (heavy)No
GYXTW24f maxPSPPE≤0.36 dB/km≤0.22 dB/km−40~+70Duct / Aerial ≤24fNo
ADSS144f maxNone (FRP)PE / AT PE≤0.36 dB/km≤0.22 dB/km−40~+70Aerial self-supportingYes
GCYFY (blown)2~288fNoneOuter sheathAir blowing in micro ductYes
EPFU (blown)CustomNonePolymerAir blowing FTTH indoorYes
GJX Drop4f maxNoneLSZH≤0.4 dB/km≤0.3 dB/kmIndoor duct (FTTH)Option
GJYX Drop4f maxNoneLSZH≤0.4 dB/km≤0.3 dB/kmAerial self-supportingOption
D-type Indoor48f maxNonePVC or LSZH≤0.4 dB/km≤0.3 dB/km−20~+60Indoor horizontalYes
B-type Indoor24f maxNonePVC or LSZH≤0.4 dB/km≤0.3 dB/km−20~+60Indoor verticalYes
Mini Distribution144f/13mm ODNoneEasy-extract≤0.4 dB/km≤0.3 dB/km−20~+60Indoor HD (data center)Yes
OPGWCustomAl-clad wireAl-cladHV power line ground wireNo