GYTA Cable
Outdoor Cable
GYTA — Duct & Aerial
Standard stranded loose-tube outdoor cable with laminated aluminum tape armor. The workhorse for duct and aerial runs.
  • Stranded loose tube with tube-filling compound
  • Steel wire central strength member
  • Armor: laminated aluminum tape (APL)
  • Black PE outer jacket
  • Attenuation: ≤0.36 dB/km @1310nm; ≤0.22 @1550nm
  • Operating temp: −40°C to +70°C
DuctAerialAPL
GYTS Cable
Outdoor Cable
GYTS — Steel Tape Armored
Corrugated steel tape armored outdoor cable with enhanced crush resistance for demanding environments.
  • Stranded loose tube construction
  • Steel wire central strength member
  • Armor: corrugated steel tape (PSP)
  • Black PE outer jacket
  • Attenuation: ≤0.36 dB/km @1310nm; ≤0.22 @1550nm
DuctAerialPSP
GYFTY Cable
Non-Metallic Cable
GYFTY — All-Dielectric Outdoor
Fully metal-free outdoor cable with FRP central strength member. Ideal for high-voltage or strong EM environments.
  • 100% metal-free construction
  • FRP non-metal central strength member
  • Longitudinal water-blocking compound
  • Black PE outer jacket
  • Operating temp: −40°C to +70°C
Non-MetalFRPHigh-EM
GYFTA Cable
Non-Metallic Cable
GYFTA(S) — FRP Armored
Metal-free alternative to GYTA/GYTS with APL or PSP armor for EM-sensitive or lightning-prone routes.
  • FRP non-metal central strength member
  • Armor: APL or PSP (selectable)
  • Black PE outer jacket
  • Operating temp: −40°C to +70°C
Non-MetalAPL/PSPOutdoor
Direct Buried Cable
Direct Buried
GYTY53 — Direct Buried
Double-jacket PSP-armored cable designed exclusively for direct buried underground installation without conduit.
  • Armor: corrugated steel tape (PSP)
  • Steel wire central strength member
  • Double black PE outer jackets
  • Max fiber count: 144
  • Operating temp: −40°C to +70°C
Direct BuriedPSPDouble Jacket
GYTA53 Cable
Direct Buried
GYTA53 — Heavy-Duty Buried
Double-armored (APL + PSP) cable for maximum mechanical protection in aggressive underground environments.
  • Double armor: APL + corrugated steel tape (PSP)
  • Steel wire central strength member
  • Double black PE outer jackets
  • Operating temp: −40°C to +70°C
Direct BuriedHeavy-DutyDouble Armor
ADSS Cable
Self-Supporting Aerial
ADSS — All-Dielectric
All-dielectric self-supporting cable with FRP central member. Fully safe for high-voltage power line corridors.
  • 100% metal-free; no grounding required
  • FRP non-metal central strength member
  • Single or double jacket option
  • Anti-tracking PE jacket available
  • Max fiber count: 144
  • Attenuation: ≤0.36 dB/km @1310nm
Self-SupportingMetal-FreeHigh-Voltage
Figure-8 Cable
Figure-8 Aerial
GY(F)TC8A(S) — Figure-8 Aerial
Figure-8 self-supporting aerial cable with stranded steel messenger wire and APL or PSP armor for long spans.
  • Messenger wire: stranded steel wires
  • Stranded loose tube design
  • Steel or FRP central strength member
  • Armor: APL or PSP options
Figure-8Self-SupportingAerial
Air Blown Cable
Air Blowing Micro Cable
GCYFY — High-Density Blown
Best blowing performance with 2–288 fibers in a compact profile for metro access and FTTH micro-duct networks.
  • Stranded loose tube; optimized blowing profile
  • Fiber count: 2 ~ 288f
  • High duct utilization; minimal initial CAPEX
  • Install: Air blowing (pneumatic micro-duct)
Air Blowing2–288fFTTH/Metro
FTTH Drop Cable
FTTH Drop Cable
GJX(F/K)H — Indoor Flat Drop
Standard FTTH indoor flat drop with LSZH jacket for horizontal in-building runs to subscriber premises.
  • Steel wire or FRP/KFRP strength members
  • Black LSZH jacket
  • Attenuation: ≤0.4 dB/km @1310nm; ≤0.3 @1550nm
  • Max fiber count: 4
  • Install: Indoor duct
FTTHIndoorLSZH
Outdoor Drop Cable
FTTH Drop Cable
GJYX(F/K)CH — Outdoor Aerial Drop
Outdoor and indoor FTTH flat drop with steel messenger wire for aerial self-supporting deployment pole to premises.
  • Messenger wire: steel wire (self-supporting)
  • FRP/KFRP/steel wire strength member
  • Black LSZH jacket
  • Install: Aerial self-supporting
FTTHAerial DropMessenger
Indoor Cable
Indoor Cable
Distribution Type — D-Type
Multi-core tight-buffer indoor distribution cable for horizontal cabling in buildings and data centers.
  • Multi-core 0.9mm tight buffered fiber
  • Aramid yarn tensile strength
  • PVC or LSZH jacket
  • Max fiber count: 48
  • Attenuation: ≤0.4 dB/km @1310nm
  • Bending radius: 10D static / 20D dynamic
IndoorHorizontal2–48f
Breakout Cable
Indoor Cable
Breakout Type — B-Type
Sub-cable unit breakout indoor cable for vertical riser cabling with excellent mechanical performance.
  • FRP central strength member; sub-cable unit
  • Aramid yarn reinforced
  • Max fiber count: 24
  • Install: Vertical and horizontal indoor cabling
IndoorVertical2–24f
OPGW Cable
Utility Cable
OPGW — Optical Ground Wire
Combines optical fiber with overhead ground wire function on high-voltage power transmission lines.
  • Variants: Central tube / Stranded tube / Al-clad SST / Al-clad PBT
  • Simultaneously grounds HV line and transmits fiber comms
  • Dual function: lightning protection + data
OPGWPower LineUtility
Media Converter
Media Converter
Fiber Optic Media Converter
Industrial and non-industrial copper-to-fiber media converters in four form factors for any deployment environment.
  • Data: 10/100/1000 Mbps
  • Non-industrial optical: SC/UPC, FC/UPC or ST/UPC; temp −10~+50°C
  • Industrial: SFP port; IP40; temp −40~+85°C
  • Forms: Standalone / Card / Rack-chassis / DIN-rail
Media ConverterIndustrialGbE
Fiber Switch
Network Switch
Fiber Optic Switch — Industrial / Non-Industrial
Multi-port fiber switches for central office and harsh outdoor environments. IP40-rated industrial DIN-rail variant.
  • Data: 10/100/1000 Mbps
  • Non-industrial: 4 or 8× RJ-45; 1× optical; −20~+60°C
  • Industrial: 2 or 4× SFP ports; IP40; −40~+85°C
  • Dim (industrial): 143×104×48mm
SwitchIndustrialIP40
Optical Transceiver
Optical Transceiver
SFP / SFP+ / XFP / QSFP / AOC
Full range of optical transceivers and active optical cables from 1.25G to 100G for all switch and router platforms.
  • Data rates: 1.25 / 2.5 / 10 / 40 / 100 Gbps
  • Transmission distance: 0.55 ~ 100 km
  • Types: SFP, XFP, SFP+, QSFP, AOC
  • Optical interfaces: LC, SC, MPO
  • Industrial temp: −40~+85°C
SFP+QSFP100GAOC
EPON OLT
PON Equipment
EPON OLT
Carrier-grade EPON Optical Line Terminal for broadband FTTH. Up to 16 PON ports; 1:64 splitting ratio.
  • Max transmission: 20 km
  • Splitting ratio: 1:64 max; Downlink: 1.25 Gbps
  • PON ports: 2 / 4 / 8 / 16; interface: SFP slot
  • Install: 1U rack mount
  • Power: Single AC / Dual AC / Dual DC
EPONOLT1U RackFTTH
GPON OLT
PON Equipment
GPON OLT
High-capacity GPON OLT with 1:128 splitting ratio and 2.5 Gbps downlink for next-generation broadband.
  • Max transmission: 20 km
  • Splitting ratio: 1:128 max; Downlink: 2.5 Gbps
  • PON ports: 8 / 16; interface: SFP slot
  • Dimensions: 442×320×44mm (1U)
  • Power: Dual AC / Dual DC
GPONOLT2.5GFTTH
ONU
PON Equipment
Dual Mode ONU — GPON/EPON
Desktop subscriber ONUs compatible with both GPON and EPON. Multiple port configs for voice, data, and CATV.
  • Downlink: 2.5 Gbps; 1× SC optical port
  • Data: 1/2/4× RJ-45; POTS: 1/2× VoIP (optional)
  • CATV: 1× RF port (optional)
  • Power: 12V/1A; temp: 0~+50°C
  • Variants: 1RJ45 / 2RJ45+VoIP+RF / 4RJ45+2VoIP
ONUGPON/EPONTriple-Play
CATV Transmitter
CATV Equipment
CATV Optical Transmitter
1U rack-mounted CATV optical transmitter for analog RF signal distribution over fiber. 1310nm and 1550nm laser options.
  • Bandwidth: 45 ~ 1000 MHz
  • Optical interface: SC/APC or FC/APC
  • Laser wavelength: 1310nm or 1550nm
  • Output power: 2~16 mW (1550nm); 2~36 mW (1310nm)
  • Transmission distance: 20 km
CATVTransmitter1310/1550nm
EDFA Amplifier
Fiber Amplifier
EDFA / EYDFA — Fiber Amplifiers
Erbium-doped fiber amplifiers for 1550nm signal amplification. Single-port EDFA and multi-port EYDFA configurations.
  • Wavelength: 1550 ± 20 nm
  • Optical interface: SC/APC or FC/APC
  • EDFA output power: 13 ~ 28 dBm; ports: 1/2/4
  • EYDFA output power: 29 ~ 44 dBm; ports: 8/16/32/64
  • Power: AC 90~265V or DC 48V
EDFAEYDFA1550nmAmplifier
ODF
Distribution Frame
ODF — Optical Distribution Frame
Floor-standing ODF for central offices and headends. Up to 720 fibers with integrated 12-core splice trays.
  • Capacity: 504f / 576f / 720f
  • 12-core integrated splice trays
  • 24/48/72/144 cores per ODF unit
  • Heights: 2m / 2.2m / 2.6m
  • Cold-rolled steel; electrostatic spraying
ODFIndoor574f
Network Cabinet
Network Cabinet
Network Cabinets — Wall & Floor Type
Full cabinet range from 6U wall-mount to 47U floor-standing with 800kg load rating.
  • Wall-mount: 6~18U; max 60 KG
  • Floor type: 22~47U; max 800 KG
  • Open frame rack: 42/47U; 4-post; 400 KG
  • Adjustable depth mounting pillars
CabinetWallFloor
Splice Closure
Splice Closure
Dome Splice Closure — IP68
IP68 dome-type splice closure in mechanical and heat shrink seal variants. Up to 672 cores, universal mounting.
  • Mechanical seal: 72 ~ 288 cores; 4~6 branch ports
  • Heat shrink seal: 96 ~ 672 cores; up to 16 branch ports
  • Protection: IP68
  • Install: Wall / Pole / Aerial / Direct bury
DomeIP68672f
Inline Closure
Splice Closure
Inline Splice Closure — IP68
Low-profile inline closure for through-cable joints. Screw or buckle fastening with mechanical or rubber sealing.
  • Capacity: 96 ~ 288 cores
  • Cable ports: 2-in-2-out or 3-in-3-out
  • Protection: IP68
  • Install: Wall / Aerial / Direct bury
InlineIP68288f
OCC Cabinet
Outdoor Cabinet
Cross-Connect Cabinet — OCC (IP65)
SMC material outdoor fiber cross-connect cabinet for street-level distribution. 96f to 1152f at IP65.
  • Capacity: 96/144/288/576/1152f
  • 12-core integrated splice trays
  • Material: SMC (non-metallic)
  • Protection: IP65
  • Install: Wall / Pole / Ground mounted
OCCIP65SMC
FAT Box
Access Terminal
FAT Box — Pre-Connect Terminal
Pre-connectorized fiber access terminal for rapid FTTH drop cable distribution at pole, wall, or aerial points.
  • 16 pre-connected adapters
  • 1 oval cable port + 2 branch ports
  • Protection: IP65
  • Install: Outdoor wall / Pole / Aerial
FAT BoxPre-ConnectIP65
OTDR
Test Equipment
OTDR — Field Unit
Portable OTDR for outdoor cable loss testing and breakpoint location. 45dB dynamic range, up to 240km range.
  • Wavelengths: 850/1300/1310/1490/1550/1625nm
  • Dynamic range: 45/43 dB (max. 240km)
  • Optional: PON power meter module
  • Built-in OPM + VFL + MCI (high-config)
OTDR45dB240km
OTDR Platform
Test Equipment
OTDR Platform — SM/MM Combined
High-precision OTDR platform combining SM and MM wavelength testing in one modular unit with 8" TFT touch screen.
  • Display: 8" TFT touch screen
  • SM + MM wavelength in one unit; 50 dB dynamic range
  • Modular: optional OPM / light source / connector inspector
OTDRSM+MMPlatform
Power Meter
Test Equipment
Optical Power Meter & Light Source
Auto-wavelength power meter with 1000-record storage, USB transfer, and matching multi-wavelength light source.
  • Light source wavelengths: 850~1625nm (1–4 selectable)
  • Power meter range: −70 ~ +6 dBm
  • 1000 records storage; USB data transfer
  • Connector: SC/FC/ST interchangeable
Power MeterLight SourceUSB
PON Power Meter
Test Equipment
PON / 10G PON Power Meters
Simultaneous multi-wavelength power meters for EPON/GPON and XGS-PON/NG-PON2 network commissioning.
  • EPON/GPON: 1310/1490/1550nm; range −35~+10 dBm
  • XGPON/NG-PON2: 1310/1490/1550/1270/1577nm; range −40~+10 dBm
  • USB data transfer
PON MeterXGPONNG-PON2
VFL
Test Equipment
VFL & Optical Cable Identifier
650nm visual fault locator for breakpoint identification up to 10km, and non-destructive live-fiber cable identifier to 40km.
  • VFL: 650nm visible red laser; 5 or 10km range
  • Cable identifier wavelength: 1550nm; range: 20 or 40km
  • Non-destructive; audio + visual signals
  • OCI battery: ≥14 hours continuous
VFLOCI40km
End Face Inspection
Test Equipment
Fiber End Inspection & IL/RL Tester
200×/400× digital end-face inspection probe and precision benchtop insertion loss / return loss test equipment.
  • End inspection: 200×/400×; 3.5" TFT LCD display
  • IL/RL tester: return loss 0~75 dB @1310/1550nm
  • IL range: −80~+10 dBm; interfaces FC/SC/ST/LC
  • Power: AC 220V (110V optional)
End-FaceIL/RL TesterProduction QC
Patchcords
Passive Components
Patchcords & Pigtails
Full range of SM and MM patchcords and pigtails across all standard connector types, polish grades, and jacket materials.
  • Connectors: SC / FC / ST / LC / E2000
  • Polish: UPC & APC; Fiber: SM & MM
  • Jacket: PVC or LSZH
  • Insertion loss: ≤0.3 dB
  • Return loss: MM ≥35; SM UPC ≥50; SM APC ≥60 dB
PatchcordPigtailSC/LC/FC
FTTA Patchcords
Passive Components
FTTA Patchcords — BBU to RRU
Specialized FTTA patchcords for 4G/5G baseband-to-remote radio unit links in all major weatherproof connector formats.
  • Variants: NSN boot / FullAXS / PDLC
  • Optimized for BBU ↔ RRU links in mobile networks
  • Low insertion loss; high return loss; SMF; UPC & APC
FTTABBU-RRU5G
Adapters
Passive Components
Fiber Optic Adapters / Couplers
SM and MM fiber adapters in all standard interfaces for mating patchcords and pigtails. Low insertion loss ≤0.2 dB.
  • Types: SC / LC / FC / ST / E2000; UPC and APC
  • Insertion loss: ≤0.2 dB; Return loss: ≥55 dB
  • Housing: Plastic or metal
AdapterCouplerSC/LC/FC
PLC Splitter
Passive Components
PLC Splitter — 1×2 to 1×128
Planar lightwave circuit splitters with excellent channel uniformity in six packaging configurations for every deployment.
  • Splitting ratio: 1×2 to 1×128
  • Return loss: ≥55 dB; Low insertion loss; Low PDL
  • Types: Blockless / Box / Insert / LGX / Rack-mount / Bare fiber
  • Fiber: SM only
PLC Splitter1×128FTTH/PON
Fast Connector
Passive Components
Fast Connector — Field Termination
Pre-polished ceramic ferrule fast connector for tool-less field termination. No epoxy or polishing equipment required.
  • Pre-embedded fiber; pre-polished ceramic ferrule
  • Success rate: >98%; Re-assemblable: 5+ cycles
  • Rated lifespan: >15 years
  • Types: SC / LC / FC
Fast ConnectorField Term.SC/LC/FC
ADSS Tension Clamp
ADSS Fittings
ADSS Tension Clamp
Preformed dead-end grip clamp for ADSS cable termination at poles and towers. Equal stress distribution, corrosion resistant.
  • Preformed armored rods; thimble clevis; shackle; extension ring
  • Equal stress distribution; no pivot stress concentration
  • Aluminum clad steel rods; hot-dip galvanized hardware
  • Pole or tower mounting
ADSSTension ClampDead-End
ADSS Suspension
ADSS Fittings
ADSS Suspension Clamp & Vibration Damper
Mid-span suspension clamp with spiral vibration damper to eliminate aeolian vibration fatigue on long aerial spans.
  • Suspension clamp: shackle + clevis eye + hosing + insert
  • Preformed armor rod option for short spans (100m)
  • Vibration damper: high elasticity; UV-stabilized; aging resistant
  • Pole or tower mounted
ADSSSuspensionDamper
ADSS Hardware
ADSS Fittings
ADSS Hardware Accessories Suite
Complete ADSS accessories including corona coil, lead-down clamp, pole clamp, tower clamp, and cable storage rack.
  • Corona coil: aluminum alloy; reduces electrical stress
  • Lead-down clamp: electro-insulating rubber type
  • Pole clamp and tower clamp: hot-dip galvanized
  • Cable storage rack: large coil space; pole or tower mount
ADSSHardwareAccessories
OPGW Fittings
OPGW Fittings
OPGW Tension & Suspension Clamps
Double-layer preformed armored rod clamps engineered specifically for OPGW cable on high-voltage transmission towers.
  • Tension: U-shackle + PH extension ring + inner/outer preformed rods
  • Suspension: ZH eye chain link + inner/outer rods + insert
  • Double-layer preformed armored rods
  • Aeolian vibration damper available
OPGWTensionSuspension
FTTH Fittings
FTTH Fittings
FTTH Drop Cable Fittings Suite
Complete hardware suite for FTTH drop cable deployment from distribution pole to subscriber premises.
  • S-type fixation; C-hook; triangle hook; spring-type splint hook
  • Metal wedge tension clamp; hoop fasten retractor; steel hoop
  • Coiling ring for vertical pole routing
  • House bracket; clamp bracket series
FTTHDrop CableHardware
Fusion Splicer
Installation Equipment
Fusion Splicer — 4 & 6 Motor
Feeder-type fusion splicers with core-to-core alignment. 4-motor and 6-motor variants for distribution and backbone cable.
  • Types: Backbone / Feeder / FTTH compact
  • Fiber: SM and MM; single core
  • Splice loss: 0.02 dB (SM); 0.01 dB (MM)
  • Splicing time: 6 seconds
  • 5" high-resolution LCD touch screen
Fusion SplicerCore AlignmentSM/MM
Cable Blowing
Installation Equipment
Cable Blowing Machines
Mini pneumatic and hydraulic cable blowing machines for blown fiber micro-duct network construction.
  • Mini pneumatic: cable 3~10mm; duct 8~20mm
  • Hydraulic: cable 8~25mm; duct 32~50mm; includes pump
  • Air compressor not included in either unit
Air BlowingMicro DuctHydraulic
Micro Ducts
Duct Infrastructure
HDPE Micro Ducts & Tube Bundles
Color-coded HDPE micro ducts and multi-sub-duct tube bundles for blown fiber network infrastructure.
  • Material: HDPE; fully dielectric; good pressure resistance
  • Color-coded for easy circuit identification
  • Micro duct sizes: 5/3.5mm through 20/16mm OD/ID
  • Tube bundles: 1/2/4/7/12/19/24 sub-duct configurations
Micro DuctHDPETube Bundle
Tool Kits
Field Toolkits
Fiber Optic Tool Kit Series
Four specialist toolkit configurations covering the complete fiber installation lifecycle from cable prep to end-face inspection.
  • TK100: Cable preparation & installation (slitter, stripper, scissors, pliers)
  • TK200: Connector polishing & field termination
  • TK300: FTTH termination kit
  • TK400: End-face inspection & cleaning (swab, cleaner, microscope)
ToolkitFTTHField
Technical Reference

Cable Specification Summary

ProductFiber CountArmorJacketAtten. @1310nmAtten. @1550nmTemp. (°C)InstallationMetal-Free
GYTACustomAPLBlack PE≤0.36 dB/km≤0.22 dB/km−40~+70Duct / AerialNo
GYTSCustomPSPBlack PE≤0.36 dB/km≤0.22 dB/km−40~+70Duct / AerialNo
GYFTYCustomNoneBlack PE≤0.36 dB/km≤0.22 dB/km−40~+70Duct / Aerial / EMYes
GYFTA(S)CustomAPL or PSPBlack PE≤0.36 dB/km≤0.22 dB/km−40~+70Duct / AerialYes
GYTY53Up to 144fPSPDouble PE≤0.36 dB/km≤0.22 dB/km−40~+70Direct buriedNo
GYTA53CustomAPL + PSPDouble PE≤0.36 dB/km≤0.22 dB/km−40~+70Direct buriedNo
ADSSUp to 144fNone (FRP)PE / Anti-track≤0.36 dB/km≤0.22 dB/km−40~+70Aerial self-supportYes
GCYFY (blown)2 ~ 288fNoneOuter sheathAir blowingYes
GJX Drop (indoor)Up to 4fNoneLSZH≤0.4 dB/km≤0.3 dB/kmIndoor duct (FTTH)Option
D-type IndoorUp to 48fNonePVC/LSZH≤0.4 dB/km≤0.3 dB/km−20~+60Indoor horizontalYes
B-type IndoorUp to 24fNonePVC/LSZH≤0.4 dB/km≤0.3 dB/km−20~+60Indoor verticalYes
OPGWCustomAl-clad wireAl-cladHV power lineNo